{"id":742,"date":"2022-10-09T16:04:49","date_gmt":"2022-10-09T16:04:49","guid":{"rendered":"https:\/\/storeplc.com\/?product=nf63-cv3p15a"},"modified":"2025-05-25T00:58:24","modified_gmt":"2025-05-25T00:58:24","slug":"nf63-cv3p15a","status":"publish","type":"product","link":"https:\/\/storeplc.com\/?product=nf63-cv3p15a","title":{"rendered":"NF63-CV3P15A"},"content":{"rendered":"<p>MOLDED CASE BREAKER 15A TRIP<\/p>\n<p>&nbsp;<\/p>\n<div class=\"row\">\n<div class=\"col-xs-12 product-section expandable-panel with-border-v2 expanded\">\n<div class=\"content fading\">\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Primary brand<\/div>\n<div class=\"col-md-9 value\">Mitsubishi<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Main function<\/div>\n<div class=\"col-md-9 value\">Moulded Case Circuit Breaker (MCCB)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Product series \/ family name<\/div>\n<div class=\"col-md-9 value\">WS-V series<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Sub-range name<\/div>\n<div class=\"col-md-9 value\">NF-C (economy class)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Functions<\/div>\n<div class=\"col-md-9 value\">Moulded \/ Molded Case Circuit Breaker (MCCB)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Poles<\/div>\n<div class=\"col-md-9 value\">3-poles (3P)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Rated current<\/div>\n<div class=\"col-md-9 value\">15A<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Trip current rating<\/div>\n<div class=\"col-md-9 value\">15 AT<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Frame current rating<\/div>\n<div class=\"col-md-9 value\">50 AF<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Rated impulse voltage (Uimp)<\/div>\n<div class=\"col-md-9 value\">8 kV<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Rated insulation voltage (Ui)<\/div>\n<div class=\"col-md-9 value\">600 V<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Connection type<\/div>\n<div class=\"col-md-9 value\">Front lugs or bars connection<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Ultimate short circuit current breaking capacity (Icu)<\/div>\n<div class=\"col-md-9 value\">2.5kA (250Vdc; IEC60947)<br \/>\n7.5kA (200Vac; IEC60947)<br \/>\n7.5kA (230Vac; IEC60947)<br \/>\n5kA (380Vac; IEC60947)<br \/>\n5kA (400Vac; IEC60947)<br \/>\n2.5kA (415Vac; IEC60947)<br \/>\n2.5kA (440Vac; IEC60947)<br \/>\n2.5kA (500Vac; IEC60947)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Service short circuit current breaking capacity (Ics)<\/div>\n<div class=\"col-md-9 value\">2.5kA (250Vdc)<br \/>\n7.5kA (200Vac)<br \/>\n7.5kA (230Vac)<br \/>\n5kA (380Vac)<br \/>\n5kA (400Vac)<br \/>\n2.5kA (415Vac)<br \/>\n2.5kA (440Vac)<br \/>\n2.5kA (500Vac)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Service short circuit current breaking capacity as a percentage of Icu (Ics%)<\/div>\n<div class=\"col-md-9 value\">(400Vac) 100 %<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Trip unit type<\/div>\n<div class=\"col-md-9 value\">Thermal-Magnetic (fixed)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Protection functions<\/div>\n<div class=\"col-md-9 value\">Thermal protection (Overload)<br \/>\nMagnetic protection (Short-circuit)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Protection settings<\/div>\n<div class=\"col-md-9 value\">Thermal protection (Overload) &#8212; tripping threshold fixed at 15A<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Mounting mode<\/div>\n<div class=\"col-md-9 value\">Surface mounting (or DIN rail with optional adapter)<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Dimensions<\/div>\n<div class=\"col-md-9 value\">W75mm x H130mm x D90mm<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Electrical durability (with load)<\/div>\n<div class=\"col-md-9 value\">(440Vac) 6000 operations<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Mechanical durability (at no load)<\/div>\n<div class=\"col-md-9 value\">10000 operations<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Utilisation category<\/div>\n<div class=\"col-md-9 value\">A<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Manufacturer product status<\/div>\n<div class=\"col-md-9 value\">Commercialized<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Equivalent to<\/div>\n<div class=\"col-md-9 value\">NF63CV3P15A<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Compliant with standard(s)<\/div>\n<div class=\"col-md-9 value\">IEC 60947-2<br \/>\nEN 60947-2<br \/>\nCE marking<br \/>\nMarine use approval NK; LR; ABS; GL<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Benefits<\/div>\n<div class=\"col-md-9 value\">The all-new &#8220;World Super V Series (WS-V Series)&#8221; built with a new breaking technology is designed to respond to the individual market needs of the receiving and distribution and machineries.<br \/>\nThis series is the result of revolutionary evolution<br \/>\nEquipped with a new cutoff technology to enhance interrupting performance<br \/>\nCompatible with the latest standards of various countries to deliver optimal performance according to individual needs.<\/div>\n<\/div>\n<div class=\"row attr-v2 with-border\">\n<div class=\"col-md-3 name\">Degree of pollution<\/div>\n<div class=\"col-md-9 value\">3<\/div>\n<\/div>\n<\/div>\n<div class=\"span text-xs-center\"><a class=\"btn toggle-expand-button btn-lg btn-sub-primary-inverted\"><span class=\"show-less\">SHOW LESS<\/span><\/a><\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-xs-12 product-section with-border expandable-panel collapsed\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>MOLDED CASE BREAKER 15A TRIP<\/p>\n","protected":false},"featured_media":3281,"template":"","meta":[],"product_brand":[],"product_cat":[41],"product_tag":[200],"class_list":["post-742","product","type-product","status-publish","has-post-thumbnail","product_cat-circuit-breakers","product_tag-nf63-cv3p15a","first","instock","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/storeplc.com\/index.php?rest_route=\/wp\/v2\/product\/742","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/storeplc.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/storeplc.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/storeplc.com\/index.php?rest_route=\/wp\/v2\/media\/3281"}],"wp:attachment":[{"href":"https:\/\/storeplc.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=742"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/storeplc.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=742"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/storeplc.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=742"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/storeplc.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=742"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}